.\" @(#)plot.1 5.1 (Berkeley) %G% .\" .TH PLOT 1G "18 January 1983" .AT 3 .SH NAME plot \- graphics filters .SH SYNOPSIS .B plot [ .BR \-T terminal [ raster ] ] .SH DESCRIPTION These commands read plotting instructions (see .IR plot (5)) from the standard input, and in general produce plotting instructions suitable for a particular .I terminal on the standard output. .PP If no .I terminal type is specified, the environment parameter $TERM (see .IR environ (7)) is used. Known .I terminals are: .TP .B 4014 Tektronix 4014 storage scope. .TP .B 450 DASI Hyterm 450 terminal (Diablo mechanism). .TP .B 300 DASI 300 or GSI terminal (Diablo mechanism). .TP .B 300S DASI 300S terminal (Diablo mechanism). .TP .B ver Versatec D1200A printer-plotter. This version of .I plot places a scan-converted image in `/usr/tmp/raster' and sends the result directly to the plotter device rather than to the standard output. The optional argument causes a previously scan-converted file .I raster to be sent to the plotter. .SH FILES /usr/bin/tek .br /usr/bin/t450 .br /usr/bin/t300 .br /usr/bin/t300s .br /usr/bin/vplot .br /usr/tmp/raster .SH "SEE ALSO" plot(3X), plot(5) .SH BUGS There is no lockout protection for /usr/tmp/raster.