assembly language, using the
systems programming language C.
consists of a main procedure which reads in the interpreter code,
a main interpreter loop which transfers successively to various
code segments implementing the abstract machine operations
and built-in procedures and functions,
the code segments themselves, and
a number of routines which support the implementation of the
Pascal input-output environment.
The interpreter runs at a fraction of the speed of equivalent
compiled C code, with this fraction varying from 1/5 to 1/15.
The fact that the interpreter implements 32 bit integer arithmetic
on a 16 bit machine notably degrades its speed.
In a code generated Pascal for a
\s-2PDP\s0-11, 32 bit integers would be undesirable.
The interpreter occupies 14.6K bytes of instruction space, which is shared
between all instances of the interpreter, and 5K bytes of data space
of which there is a copy for each interpreter execution.
The interpreter occupies 14.6K bytes of instruction space, shared among
all processes executing Pascal, and has 4.6K bytes of data space (constants,
error messages, etc.) a copy of which is allocated to each executing process.
Format of the object file
normally interprets the code left in an object file by a run of the
The file where the translator puts the object originally, and the most
commonly interpreted file, is called
We will first describe the way the object file was prepared in version 1.0
In version 1.0 of the interpreter, the
file has an extremely simple format.
The first word of the file has the octal value 404,
like the numbers 407, 410, and 411 which signify executable files to the
can be recognized by a modified shell (command interpreter)
which can then fork instances of
In this way, Pascal objects can be referred to at the shell level by typing
The modified shell can open each file which is executable
but does not have a magic number recognized by the operating system.
If the first word of such a file is 404, then the shell recognizes
the file as a Pascal object, and creates an instance of the Pascal
interpreter with the specified file as its first argument.
This, importantly, allows all processes executing Pascal objects to share
the same interpreter, and allows the Pascal object files to be small
as they do not contain a copy of the interpreter.
With version 1.1 of the Pascal system an option exists to have the translator
prepare true executable files. In order that all persons using
share a common text image, this executable file is not an interpreter,
but rather a small process which coordinates with the iinterpreter to start
The way in which this happens is somewhat complicated.
When one of these object files is created, the interpreter code is placed
at the end of a special ``header'' file and the size of the initialized
data area of this header file is expanded to include this code.
When the process executes, the interpreter code is thus available at a
easily determined address in its data space.
When executed, the object process creates an
creates another process by doing a
and arranges that the resulting parent process becomes an instance of
The child process then writes, through the pipe whicch it has to the parent,
interpreter process, the interpreter code.
When this process is complete, the child exits.
The real advantage of this approach is that it does not require modifications
to the shell, and that the resultant objects are ``true objects'' not
requiring special treatment.
A simpler mechanism would be to determine the name of the file which was
executed and pass this to the interpreter.
However it is not possible to determine this name in all cases.\u\*(dg\d
\*(dgFor instance, if the
program is placed in the directory
the first argument to the program, nominally the programs name, is
While it would be possible to search in the standard place,
i.e. the current directory, and the system directories
for a corresponding object file,
this would be expensive and not guaranteed to succeed.
Several shells exist which allow other directories to be searched
for commands, and there is,
no way to determine what these directories are.
After the first word containing the value 404,
file contains the object code.
General features of object code
Pascal object code is relocatable as all addressing references for
control transfers within the code are relative.
The code consists of instructions interspersed with inline data.
All instructions have a length which is an even number of bytes,
that is, an integral number of words.
No variables are kept in the object code area.
The first byte of a Pascal interpreter instruction contains an operation
This allows a total of 256 major operation codes, and 219 of these are
The second byte of each interpreter instruction is called the
It contains a small integer which may, for example, be used as a
block-structure level for the associated operation.
If the instruction can take a fullword constant,
this constant is often packed into the subop
if it fits into 8 bits and is not zero.
A subop value of 0 indicates that the constant wouldn't
fit and therefore follows in the next word.
This is a space optimization, the value of 0 for flagging
the longer case being convenient because it is easy to test.
Other instruction formats are used.
instructions take an offset in the following word,
operators which load constants onto the stack
take arbitrarily long inline constant values,
and a large number of operations deal exclusively with data on the
interpreter stack, requiring no inline data.
Stack structure of the interpreter
The interpreter emulates a stack-structured Pascal machine.
The ``load'' instructions put values onto the stack, where all
arithmetic operations take place.
The ``store'' instructions take values off the stack
and place them in an address which is also contained on the stack.
The only way to move data or to compute in the machine is with the stack.
To make the interpreter operations more powerful
and to thereby increase the interpreter speed,
the arithmetic operations in the interpreter are ``typed''.
That is, length conversion of arithmetic values occurs when they are
This eliminates the need for interpreter cycles for length conversion
and the associated overhead.
For example, when adding an integer which fits in one byte to one which
requires four bytes to store, no ``conversion'' operators are required.
The one byte integer is loaded onto the stack, followed by the four
byte integer, and then an adding operator is used which has, implicit
in its definition, the sizes of the arguments.
Data types in the interpreter
The interpreter deals with several different fundamental data types.
In the memory of the machine, 1, 2, and 4 byte integers are supported,
with only 2 and 4 byte integers being present on the stack.
The interpreter always converts to 4 byte integers when there is a possibility
of overflowing the shorter formats.
This corresponds to the Pascal language definition of overflow in
arithmetic operations which requires that the result be correct
if all partial values lie within the bounds of the base integer type:
Character constants are treated similarly to 1 byte integers for
most purposes, as are Boolean values.
All enumerated types are, in fact, treated as integer values of
an appropriate length, usually 1 byte.
The interpreter also has real numbers, occupying 8 bytes of storage,
and sets and strings of varying length.
The appropriate operations are included for each data type, such as
set union and intersection and an operation to write a string
which is on top of the stack to a file.
data formats are supported by the interpreter.
The smallest unit of storage occupied by any variable is one byte.
thus degenerate to simple memory to memory transfers with
The interpreter runtime environment uses a stack data area and a heap
data area, which are kept at opposite ends of memory
and grow towards each other.
All global variables and variables local to procedures and functions
are kept in the stack area.
Dynamically allocated variables and buffers for input/output are
The addressing of block structured variables is accomplished through
a fixed display which contains, for each
statically active block, the address of its stack frame.\*(dg
\*(dg Here ``block'' is being used to mean any
This display is referenced by instructions which load and store
variables and maintained by the operations for
block entry and exit, and for non-local
Three ``global'' variables in the interpreter, in addition to the
is a pointer to the display entry for the current block;
is the abstract machine location counter;
is a register which holds the address of the main interpreter
loop so that returning to the loop to fetch the next instruction is
The stack frame structure
has a stack frame consisting of three parts:
a block mark, local variables, and temporary storage for partially
The stack in the interpreter grows from the high addresses in memory
so that those parts of the stack frame which are ``on the top''
of the stack have the most negative offsets from the display
The major parts of the stack frame are represented in Figure 1.1.
Note that the local variables of each block
have negative offsets from the corresponding display entry,
the ``first'' local variable having offset `\-2'.
The block mark contains the saved information necessary
to restore the environment when the current block exits.
It consists of two parts.
The first and top-most part is saved by the
instruction in the interpreter.
This information is not present for the main program
as it is never ``called''.
The second part of the block mark is created by the
begin block operator which also allocates and clears the
The format of these blocks is represented in Figure 1.2.
operator includes the line number
which is printed if the program execution terminates abnormally;
giving the return address;
and the current display entry address
begin operator saves the previous display contents at the level
of this block, so that the display can be restored on block exit.
A pointer to 10 bytes of information giving the first eight characters of the
name of this block and its beginning line number is also saved.
This information is stored in the intepretor object code in-line after the
It is used in printing a post-mortem backtrace.
The saved file name and buffer reference are necessary because of
the input/output structure
(this is discussed in detail in
The top of stack reference gives the value the stack pointer should
have when there are no expression temporaries on the stack.
It is used for a consistency check in the
line number operators in the interpreter, which occurs before
This helps to catch bugs in the interpreter, which often manifest
themselves by leaving the stack non-empty between statements.
Note that there is no explicit static link here.
Thus to set up the display correctly after a non-local
statement one must ``unwind''
through all the block marks on the stack to rebuild the display.
Arguments and return values
A function returns its value into a space reserved by the calling
are placed on top of this return area.
calls, arguments are placed at the end of the expression evaluation area
completes, expression evaluation can continue
after popping the arguments to the
exactly as if the function value had been ``loaded''.
are also popped off the stack by the caller
after its execution terminates.
As a simple example consider the following stack structure
the calling sequence for this function would be:
to clear space for the return value,
on the stack with an ``rvalue'' operator,
and can then complete evaluation of the containing expression.
The operations used here will be explained in section 2.
10 \*bfunction\fR f(i: integer): real;
would have code sequence:
operator takes 12 bytes of inline data.
The first word indicates the amount of local variable storage, here none.
The succeeding two lines give the name of the block and the line number
operator places a pointer to the name and line number in the block mark.
here involved taking an address of the
using the address of operator
The next operation in the interpretation of this function is the loading
and the first variable in the local variable area.
completes by assigning the 4 byte integer on the stack to the 8 byte
return location, hence the
assignment operator, and then uses the
operator to exit the current block.
The main interpreter loop
We can now describe the main interpreter loop.
It is actually quite short:
First the main operation code is extracted from the first byte of
The code will be a small integer in the range -128 to 127.
It is then doubled to make a word index into the operation table.
Note that the sub-operation code is placed in register 3, and is thus available
for use by the individual operation sequences.
The hardware also leaves the condition codes set based on the value of this
The code will be discussed in section 2.1.
is in the middle of a branch table which has one operation address
The table is generated automatically from an abstract machine
The address of the instruction at
is always contained in the register variable
so that a return to the main interpreter loop both is quick and occupies
The return is thus a ``jmp\ (lp)'' instruction,
defined for mnemonic value as the operator ``return'' in the intepreter, i.e.
so that one can write the mnemonic ``return'' at the end of an interpreter
Errors during interpretation cause a subroutine call to an error routine
in a conventional fashion. An earlier version of the interpreter
more compactly represented the raising of these conditions by using emulator
traps (\s-2EMT\s0s), a form of system call otherwise unused by \s-2UNIX\s0.
Errors were assigned small integer numbers and then referred to
symbolically in the interpreter.
The \s-2UNIX\s0 assember,
provides a mechanism for defining the opcode ``error'' to be an ``emt,'' i.e.:
Thus there were many lines like
These cause a process fault,
which is trapped by the system and passed to the label
in the interpreter which fetches the error code byte from the
instruction and calls the procedure
processes the error condition,
printing an appropriate error message and, usually, a backtrace.
In order that the interpreter run on a standard \s-2UNIX\s0 without
using non-standard system calls to fetch the \s-2EMT\s0 code
when running in separated instruction and data spaces,
the current version of the interpreter places the error code in a global
variable, before doing an
is used to compactly transfer control, but not for argument transmission.